800W Switching Power Supply
Output Power: 800W
Input voltage: AC100-120V / 200-240V
Output Voltage: 12/24/36/48/70/80/100/200VDC
- Output Power
- 800W
- Output Voltage
- 12/15/18/20/24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300VDC
- Output Current
- 0-66A
- Input Voltage
- AC100-120V / 200-240V
- Brand
- SSPELE
- Application
- Hospital,Engineering Project,Electric Lab,LED Lighting
- Quality
- Government Engineering,ISO9001,CE&Rohs,UL
- Payment
- T/T, L/C, Western Union,Paypal,MoneyGram
- Quantity
- 50000 PCS Per Month
- Packing
- Suitable Packing For Sea/Air Transport
- Material
- Aluminum,PCB
- Place of Origin
- Zhejiang,China
- Ripple&Noise
- 150mVp-p
Features:
- High efficiency, high reliability
- For AC power supply input global
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Built-in fan switch control
- PFC correction, built-in distance open/shutdown and voltage compensation signal interface
- Size: 240*124*65mm(L*W*H)
- Output Voltage Customized: 12/15/18/20/24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300VDC
model | SS-800 -12 |
SS-800 -24 |
SS-800 -36 |
SS-800 -48 |
SS-800 -60 |
SS-800 -80 |
SS-800 -100 |
|
output | Dc output voltage | 12V | 24V | 36V | 48V | 60V | 80V | 100V |
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated output current | 7A | 33A | 22A | 16.6A | 13.3A | 10A | 8A | |
Output current range | 0-7A | 0-33A | 0-22A | 0-16.6A | 0-13.3A | 0-10A | 0-8A | |
Output power | 800W | 800W | 800W | 800W | 800W | 800W | 800W | |
Ripple and the noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
Dc voltage adjustable scope | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | |
Start, rise, keep time | 1.5s,50ms,20ms Loaded with | |||||||
input | Input voltage range | 100-120VAC or 200-240VAC | ||||||
Power factor | PF>0.95/230VAC PF>0.95/115VAC Loaded with | |||||||
Exchange input current | 7A/115 V 3.5A/ 230 V | |||||||
efficiency | 86% | 82% | 83% | 85% | 86% | 86% | 86% | |
Impulse current | 18A/115V 36A/230V | |||||||
Leakage current | <3.5mA/240VAC | |||||||
Protection characteristics | Overload protection | 105%~135% | ||||||
Protection way: current limiting, automatic recovery | ||||||||
Overvoltage protection | 115%~135% | |||||||
Protection way: hiccups, auto recovery mode | ||||||||
environment | Working temperature, humidity | -10℃~+50℃;20%~90 %RH | ||||||
Keep temperature, humidity | -20℃~+85℃;10%~95 %RH | |||||||
Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | |||||||
security | Compression sex | 3: KVAC between input and output and input and output KVAC: 1.5 to: 0.5KVAC |
||||||
Insulation resistance | Between the input and output, the input and output, and ground: 100M Ohms/500VDC |
|||||||
standards | Insulation resistance | Accord with UL1950,TUV EN60950 |
||||||
EMC standard | Accord with EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204 |
|||||||
other | weight | 2Kg | ||||||
packaging | 12pcs/24kg/1.22CUFT | |||||||
note | All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. |