Products

1200W Switching Power Supply

Features: High efficiency, high reliability For AC power supply input global 100% full load and machine test
Output Power
1200W
Output Voltage
12/15/18/20/24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300VDC
Output Current
0-100A
Input Voltage
AC100-120V or 200-240V
Brand
SSPELE
Application
Hospital,Engineering Project,Electric Lab,LED Lighting
Quality
Government Engineering,ISO9001,CE&Rohs,UL
Payment
T/T, L/C, Western Union,Paypal,MoneyGram
Quantity
50000 PCS Per Month
Packing
Suitable Packing For Sea/Air Transport
Material
Aluminum,PCB
Place of Origin
Zhejiang,China
Ripple&Noise
150mVp-p

Features:

  • High efficiency, high reliability
  • For AC power supply input global
  • 100% full load and machine test
  • Protection characteristics: short circuit/overload/pressure
  • Built-in dc electric fan forced air cooling
  • Built-in fan switch control
  • PFC correction, built-in distance open/shutdown and voltage compensation signal interface
  • Size: 291*132*68mm(L*W*H)
  • Output Voltage Customized: 12/15/18/20/24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300VDC
model SS-1200
-12
SS-1200
-24
SS-1200
-30
SS-1200
-48
SS-1200
-60
SS-1200
-80
SS-1200
-90
output Dc output voltage 12V 24V 30V 48V 60V 80V 90V
Output voltage tolerance ±1% ±1% ±1% ±1% ±1% ±1% ±1%
Rated output current 100A 50A 40A 25A 20A 15A 13A
Output current range 0-100A 0-50A 0-40A 0-25A 0-20A 0-15A 0-13A
Output power 1200W 1200W 1200W 1200W 1200W 1200W 1200W
Ripple and the noise 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 150mVp-p
Dc voltage adjustable scope -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10%
Start, rise, keep time 1.5s,50ms,20ms Loaded with
input Input voltage range 100-120VAC or 200-240VAC
Power factor PF>0.95/230VAC PF>0.95/115VAC Loaded with
Exchange input current 7A/115 V 3.5A/ 230 V
efficiency 86% 82% 83% 85% 86% 86% 86%
Impulse current 18A/115V 36A/230V
Leakage current <3.5mA/240VAC
Protection characteristics Overload protection 105%~135%
Protection way: current limiting, automatic recovery
Overvoltage protection 115%~135%
Protection way: hiccups, auto recovery mode
environment Working temperature, humidity -10℃~+50℃;20%~90 %RH
Keep temperature, humidity -20℃~+85℃;10%~95 %RH
Vibrate resistance 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis
security Compression sex 3: KVAC between input and output and input and output KVAC: 1.5 to:
0.5KVAC
Insulation resistance Between the input and output, the input and output, and ground:
100M Ohms/500VDC
standards Insulation resistance Accord with
UL1950,TUV EN60950
EMC standard Accord with
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204
other weight 3Kg
packaging 8pcs/24kg/1.22CUFT
note All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃conditions measuring income value.
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.
Specific output current see output drop forehead curve.

Feedback