SPECIFICATIONS |
OUTPUT |
|
Model |
SHAF-2000-60 |
SHAF-2000-150 |
SHAF-2000-24 |
SHAF-2000-110 |
SHAF-2000-36 |
SHAF-2000-48 |
DC Voltage |
60V |
150V |
24V |
110V |
36V |
48V |
Rated Current |
33A |
13.3A |
80A |
18A |
55A |
41A |
Current Range |
0-33A |
0-13.3A |
0-80A |
0-18A |
0-55A |
0-41A |
Rated Power |
2000W |
2000W |
1000W |
2000W |
2000W |
2000W |
Ripple&Noise |
200mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
200mVp-p |
Voltage Adj. Range |
0-60V |
0-150V |
0-24V |
0-110V |
0-36V |
0-48V |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Load Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
Setup,Rise,Hold Up Time |
1.5s,50ms,20msat full load |
|
|
INPUT |
|
Voltage Range |
AC110-240V |
AC Current |
|
Efficiency |
90% |
90% |
90% |
90% |
90% |
90% |
Inrush Current |
|
Leakage Current |
|
|
|
PROTECTION |
|
Over Load |
115% |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
Over Voltage |
|
|
|
|
|
|
Over Temp. |
≥55℃Fan On≤45℃Fan Off ≥70℃ Output Cutout |
|
|
ENVIRONMENT |
|
Working Temp.Humidity |
-25℃~+50℃; 20%~90%RH |
Storage Temp.Humidity |
-20℃~+85℃; 10%~95%RH |
Temp.Coefficient |
±0.03%/℃(0~50℃) |
Vibration |
10~500Hz,2G 10min,/11cycle,60min,each axes |
|
|
SAFETY |
|
Withstand Voltage |
I/P-O/P:3KVACI/P-FG:1.5KVACI/P-FG:0.5KVAC |
Isolation Resistance |
I/P-O/P,I/P-FG,I/P-FG:500VDC/100MΩ |
|
|
STANDARD |
|
Safety Standard |
UL1950 |
EMCStandard |
CISPR22(EN 55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000-3-2 |
|
|
OTHERS |
|
Dimension |
280*140*65mm(L*W*H) |
Weight |
3.5kg |
|
|
NOTE |
|
1.All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature. 2.Tolerance:includes set up tolerance,line regulation and load regulation 3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ&47μ parallel capacitor. 4.Line regulation:min&max voltage of the rated load. 5.Load regulation:load from 0 to 100% |