900W Output Adjustable Switch Mode Power Supply
Features:
High reliability, low ripple
Switch input voltage range choice
Protection characteristics: short circ
- Output Power
- 900W
- Output Voltage
- 0-400/500/550/600/700/800/900/1000/1100/1200V DC Adjustable
- Output Current
- 0-2.25A
- Input Voltage
- AC100-120V or 200-240V (Optional)
- Brand
- SSPELE
- Application
- Hospital,Engineering Project,Electric Lab,LED Lighting,High Voltage Facility
- Quality
- Government Engineering,ISO9001,CE&Rohs,UL
- Payment
- T/T, L/C, Western Union,Paypal,MoneyGram
- Quantity
- 50000 PCS Per Month
- Packing
- Suitable Packing For Sea / Air Transport
- Material
- Aluminum,PCB
- Place of Origin
- Zhejiang,China
- Ripple&Noise
- 500mVp-p
Features:
- High reliability, low ripple
- Switch input voltage range choice
- Protection characteristics: short circuit/overload/pressure/thermal
- Built-in distance open/shutdown and voltage compensation signal interface
- Has the parallel function
- Built-in dc electric fan forced air cooling
- Size : 265*186*70mm (L*W*H)
- Output Voltage Customized: 0-400/500/550/600/700/800/900/1000/1100/1200V DC Adjustable
model | SHA-900-900 | SHA-900-600 | SHA-900-500 | SHA-900-400 | SHA-900-450 | SHA-900-700 | SHA-900-800 | ||
output | Dc output voltage | 0-900V | 0-600V | 0-500V | 0-400V | 0-450V | 0-700V | 0-800V | |
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ||
Rated output current | 1A | 1.5A | 1.8A | 2.2A | 2A | 1.28A | 1.12A | ||
Output current range | 0-1A | 0-1.5A | 0-1.8A | 0-2.2A | 0-2A | 0-1.28A | 0-1.12A | ||
Output power | 900W | 900W | 900W | 900W | 900W | 900W | 900W | ||
Ripple and the noise | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | ||
Dc voltage adjustable scope | 0-400/500/550/600/700/800/900/1000/1100/1200V DC Adjustable | ||||||||
Start, rise, keep time | 800ms, 50ms, 16ms Loaded with | ||||||||
input | Input voltage range | 200~240 VAC 47~63 Hz | |||||||
Exchange input current | 13A/115 VAC 8.0A/ 230 VAC | ||||||||
efficiency | 80% | 81% | 85% | 87% | 87% | 87% | 87% | ||
Impulse current | 60A/230V | ||||||||
Leakage current | 3.5 mA/240VAC | ||||||||
Protection characteristics | Overload protection | 110%~135% | |||||||
Protection way: current limiting, delay shut off, restart | |||||||||
Overvoltage protection | 110%~135% | ||||||||
Protection way: cut output, restart | |||||||||
High temperature protection | TSW1 (power tube) temperature > 100 ℃, restart when cut off output | ||||||||
environment | Working temperature, humidity | -10℃~+65℃,20%~90 %RH | |||||||
Keep temperature, humidity | -20℃~+85℃,10%~95 %RH | ||||||||
Vibrate resistance | 10~200Hz,2G 10min.. / 1 cycle time, 60 minutes, the axis | ||||||||
security | Compression sex | I/P-O/P, I/P-FG:1500VAC | |||||||
Insulation resistance | I/P-O/P, I/P-FG, >100M Ohms / 500VDC | ||||||||
standards | Safety standards | Accord with UL1950,CSA22.2,IEC60950 |
|||||||
EMC standard | Accord with FCC Part 15 Class A |
||||||||
other | weight | 4.5Kg; | |||||||
packaging | 8pcs/34.0kg/CARTON | ||||||||
note | 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25℃ conditions measuring income value. 2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. 3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. 4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |