500W Output Adjustable Switch Mode Power Supply
Features:
High efficiency, high reliability
For AC power supply input global
100% full load and machine test
- Output Power
- 500W
- Output Voltage
- 0-24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300V DC Adjustable
- Output Current
- 0-20A
- Input Voltage
- AC100-120V or 200-240V (Optional)
- Brand
- SSPELE
- Application
- Hospital,Engineering Project,Electric Lab,LED Lighting
- Quality
- Government Engineering,ISO9001,CE&Rohs,UL
- Payment
- T/T, L/C, Western Union,Paypal,MoneyGram
- Quantity
- 100000 PCS Per Month
- Packing
- Suitable Packing For Sea / Air Transport
- Material
- Aluminum,PCB
- Place of Origin
- Zhejiang,China
- Ripple&Noise
- 180mVp-p
Features:
- High efficiency, high reliability
- For AC power supply input global
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Built-in fan switch control
- PFC correction, built-in distance open/shutdown and voltage compensation signal interface
- Size: 260*105*65mm(L*W*H)
- Output Voltage Customized: 0-24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300V DC Adjustable
model | SA-500 -300 |
SA-500 -200 |
SA-500 -150 |
SA-500 -100 |
SA-500 -80 |
SA-500 -60 |
SA-500 -250 |
|
output | Dc output voltage | 0-300V | 0-200V | 0-150V | 0-100V | 0-80V | 0-60V | 0-250V |
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated output current | 1.66A | 2.5A | 3.3A | 5A | 6.5A | 8.5A | 2A | |
Output current range | 0-1.66A | 0-2.5A | 0-3.3A | 0-5A | 0-6.5A | 0-8.5A | 0-2A | |
Output power | 500W | 500W | 500W | 500W | 500W | 500W | 500W | |
Ripple and the noise | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | 180mVp-p | 200mVp-p | |
Dc voltage adjustable scope | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | |
Start, rise, keep time | 1.5s,50ms,20ms Loaded with | |||||||
input | Input voltage range | 100-120VAC or 200-240VAC | ||||||
Power factor | PF>0.95/230VAC PF>0.95/115VAC Loaded with | |||||||
Exchange input current | 7A/115 V 3.5A/ 230 V | |||||||
efficiency | 81% | 82% | 83% | 85.5% | 86.5% | 87% | 87% | |
Impulse current | 18A/115V 36A/230V | |||||||
Leakage current | <3.5mA/240VAC | |||||||
Protection characteristics | Overload protection | 105%~135% | ||||||
Protection way: current limiting, automatic recovery | ||||||||
Overvoltage protection | 115%~135% | |||||||
Protection way: hiccups, auto recovery mode | ||||||||
environment | Working temperature, humidity | -10℃~+50℃;20%~90 %RH | ||||||
Keep temperature, humidity | -20℃~+85℃;10%~95 %RH | |||||||
Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | |||||||
security | Compression sex | 3: KVAC between input and output and input and output KVAC: 1.5 to: 0.5KVAC |
||||||
Insulation resistance | Between the input and output, the input and output, and ground: 100M Ohms/500VDC |
|||||||
standards | Insulation resistance | Accord with UL1950,TUV EN60950 |
||||||
EMC standard | Accord with EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204 |
|||||||
other | weight | 1.5Kg | ||||||
packaging | 15pcs/22.5kg/1.22CUFT | |||||||
note | All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25℃ conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. |