Products

SD-60

60WSingle Output DC-DCConverter SD-60 series Features: 2:1 wide input range Protections: Short circuit / Overload /

60WSingle Output DC-DCConverter SD-60 series

Features:

  • 2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage
  • 1500VAC I/O isolation
  • Built-in EMI filter, low ripple noise
  • 100% full load burn-in test
  • Fixed switching frequency at 83 KHz
  • Low cost
  • High reliability
  • 2 years warranty
SPECIFICATION
OUTPUT  
Model SD-60A-5 SD-60B-5 SD-60C-5 SD-60D-12 SD-60A-12 SD-60B-12 SD-60C-12 SD-60D-12 SD-60A-24 SD-60B-24 SD-60C-24 SD-60D-24
DC Voltage 5V 12V 24V
Rated Current 12A 5A 2.5A
Current Range 0~12A 0~5A 0~2.5A
Rated Power 60W 60W 60W
Ripple & Noise 100mVp-p 120mVp-p 150mVp-p
Voltage Adj. Range 4.5~5.5VDC 11~16VDC 23~30VDC
Voltage Tolerance ±2.0% ±1.0% ±1.0%
Line Regulation ±0.5% ±0.3% ±0.2%
Load Regulation ±0.5% ±0.3% ±0.2%
Setup, Rise, Hold Up Time 2.5s,50ms,------at full load
   
INPUT  
Voltage Range A:9.2~18VDCB:19~36VDC  C:36~72VDCD:73~144VDC
Efficiency 70% 73% 76% 72% 75% 78% 74% 80% 83%
DC Current 7A/12V 3A/24V 1.5A/48V
   
PROTECTION  
Over Load 105~150% rated output power
Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over Voltage 5.75~6.75V/10%load 16.8~20V/10%load 31.5~37.5V/10%load
Protection type:Hiccup mode,recovers automatically after fault condition is removed
   
ENVIRONMENT  
Working Temp. -10~+60℃ (Refer to "Derating Curve")
Working Humidity 20~90% RH non-condensing
Storagetemp.,Humidity -20~+85℃ ,10~95%RH
Temp.Coefficient ±0.03%/℃ (0~50℃)
Vibration 10~500Hz,2G10min./1cycle,60min.each along X, Y,Z axes
   
SAFETY &EMC  
Safety Standards Design refer to LVD
Withstand Voltage I/P-O/P:1.5KVAC   I/P-FG:1.5KVAC   O/P-FG:0.5KVAC  
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC /25℃ /70%RH  
EMC Emission Compliance to EN55022(CISPR22)Class B
EMC Immunity Compliance to EN61000-4-2,3,4,6,8, EN55024, heavy industry level, criteria A
   
OTHERS  
Dimension 159*97*38mm(L*W*H)
Weight 0.48Kg
Packing 24pcs/12.7Kg/0.75CUFT
   
NOTE  
1. All parameters NOT specially mentioned are measured at 12,24,48VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meetsEMC directives.

SD-60

SD-60