500W 0-500VDC 1A Output Adjustable Switching Power Supply with CE
Features:
High reliability, low ripple
Switch input voltage range choice
Protection characteristics: short circ
- Output Power
- 500W
- Output Voltage
- 0-500VDC Adjustable
- Output Current
- 1A
- Brand
- SSPELE
|
||||||||
model | SHA-500-500 | SHA-500-450 | SHA-500-400 | SHA-500-350 | ||||
output | Dc output voltage | 0-500V | 0-450V | 0-400V | 0-350V | |||
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ||||
Rated output current | 1A | 1.1A | 1.2A | 1.4A | ||||
Output current range | 0-1A | 0-1.1A | 0-1.2A | 0-1.4A | ||||
Output power | 500W | 500W | 500W | 500W | ||||
Ripple and the noise | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | ||||
Dc voltage adjustable scope | ||||||||
Start, rise, keep time | 800ms, 50ms, 16ms Loaded with | |||||||
input | Input voltage range | 200~240 VAC47~63 Hz | ||||||
Exchange input current | 13A/115 VAC 8.0A/ 230 VAC | |||||||
efficiency | 80% | 81% | 85% | 87% | ||||
Impulse current | 60A/230V | |||||||
Leakage current | 3.5 mA/240VAC | |||||||
Protection characteristics | Overload protection | 110%~135% | ||||||
Protection way: current limiting, delay shut off, restart | ||||||||
Overvoltage protection | 110%~135% | |||||||
Protection way: cut output, restart | ||||||||
High temperature protection | TSW1 (power tube) temperature > 100 ℃, restart when cut off output | |||||||
environment | Working temperature, humidity | -10℃~+65℃,20%~90 %RH | ||||||
Keep temperature, humidity | -20℃~+85℃,10%~95 %RH | |||||||
Vibrate resistance | 10~200Hz,2G 10min.. / 1 cycle time, 60 minutes, the axis | |||||||
security | Compression sex | I/P-O/P, I/P-FG:1500VAC | ||||||
Insulation resistance | I/P-O/P, I/P-FG, >100M Ohms / 500VDC | |||||||
standards | Safety standards | Accord with UL1950,CSA22.2,IEC60950 |
||||||
EMC standard | Accord with FCC Part 15 Class A |
|||||||
other | weight | 4.5Kg; | ||||||
packaging | 8pcs/34.0kg/CARTON | |||||||
note | 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25℃ conditions measuring income value. 2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. 3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. 4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |