Products

500W 0-300VDC Output Adjustable Switching Power Supply with CE

Features: High efficiency, high reliability For AC power supply input global 100% full load and machine test
Output Power
500W
Output Voltage
0-300VDC Adjustable (By Potentiometer)
Output Current
1.6A
Input Voltage
AC100-120V or 200-240V (Optional)
Brand
SSPELE
Application
Hospital,Engineering Project,Electric Lab,LED Lighting
Quality
Government Engineering,ISO9001,CE&Rohs,UL
Payment
T/T, L/C, Western Union,Paypal,MoneyGram
Quantity
100000 PCS Per Month
Packing
Suitable Packing For Sea / Air Transport
Material
Aluminum,PCB
Place of Origin
Zhejiang,China
Ripple&Noise
180mVp-p

Features:

  • High efficiency, high reliability
  • For AC power supply input global
  • 100% full load and machine test
  • Protection characteristics: short circuit/overload/pressure
  • Built-in dc electric fan forced air cooling
  • Built-in fan switch control
  • PFC correction, built-in distance open/shutdown and voltage compensation signal interface
  • Size: 260*105*65mm(L*W*H)
  • Output Voltage Customized: 0-24/28/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300V DC Adjustable

 

model SA-500
-300
SA-500
-200
SA-500
-150
SA-500
-100
SA-500
-80
SA-500
-60
SA-500
-250
SA-500
-120
SA-500
-220
SA-500
-110
output Dc output voltage 0-300V 0-200V 0-150V 0-100V 0-80V 0-60V 0-250V 0-120V 0-220V 0-110V
Output voltage tolerance ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1% ±1%
Rated output current 1.66A 2.5A 3.3A 5A 6.5A 8.5A 2A 4.1A 2.2A 4.5A
Output current range 0-1.66A 0-2.5A 0-3.3A 0-5A 0-6.5A 0-8.5A 0-2A 0-4.1A 0-2.2A 0-4.5A
Output power 500W 500W 500W 500W 500W 500W 500W 500W 500W 500W
Ripple and the noise 200mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p 180mVp-p 200mVp-p 200mVp-p 200mVp-p 200mVp-p
Dc voltage adjustable scope -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10% -10%,+10%
Start, rise, keep time 1.5s,50ms,20ms Loaded with
input Input voltage range 100-120VAC or 200-240VAC
Power factor PF>0.95/230VAC PF>0.95/115VAC Loaded with
Exchange input current 7A/115 V 3.5A/ 230 V
efficiency 81% 82% 83% 85.5% 86.5% 87% 87% 87% 87% 87%
Impulse current 18A/115V 36A/230V
Leakage current <3.5mA/240VAC
Protection characteristics Overload protection 105%~135%
Protection way: current limiting, automatic recovery
Overvoltage protection 115%~135%
Protection way: hiccups, auto recovery mode
environment Working temperature, humidity -10℃~+50℃;20%~90 %RH
Keep temperature, humidity -20℃~+85℃;10%~95 %RH
Vibrate resistance 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis
security Compression sex 3: KVAC between input and output and input and output KVAC: 1.5 to:
0.5KVAC
Insulation resistance Between the input and output, the input and output, and ground:
100M Ohms/500VDC
standards Insulation resistance Accord with
UL1950,TUV EN60950
EMC standard Accord with
EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204
other weight 1.5Kg
packaging 15pcs/22.5kg/1.22CUFT
note All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25℃ conditions measuring income value.
Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement.
Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate.
The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index.
Specific output current see output drop forehead curve.

Feedback