500W 0-150VDC Output Adjustable Switching Power Supply with CE
Features:
High efficiency, high reliability
For AC power supply input global
100% full load and machine test
- Output Power
- 500W
- Output Voltage
- 0-150VDC Adjustable (By Potentiometer)
- Output Current
- 3.3A
- Input Voltage
- AC100-120V or 200-240V (Optional)
- Brand
- SSPELE
- Quality
- Government Engineering
|
|||||||||
model | SA-500 -300 |
SA-500 -200 |
SA-500 -150 |
SA-500 -100 |
SA-500 -80 |
SA-500 -60 |
|||
output | Dc output voltage | 0-300V | 0-200V | 0-150V | 0-100V | 0-80V | 0-60V | ||
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |||
Rated output current | 1.66A | 2.5A | 3.3A | 5A | 6.5A | 8.5A | |||
Output current range | 0-1.66A | 0-2.5A | 0-3.3A | 0-5A | 0-6.5A | 0-8.5A | |||
Output power | 500W | 500W | 500W | 500W | 500W | 500W | |||
Ripple and the noise | 300mVp-p | 280mVp-p | 260mVp-p | 240mVp-p | 200mVp-p | 180mVp-p | |||
Dc voltage adjustable scope | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | |||
Start, rise, keep time | 1.5s,50ms,20ms Loaded with | ||||||||
input | Input voltage range | 100-120VAC or 200-240VAC | |||||||
Power factor | PF>0.95/230VAC PF>0.95/115VAC Loaded with | ||||||||
Exchange input current | 7A/115 V 3.5A/ 230 V | ||||||||
efficiency | 81% | 82% | 83% | 85.5% | 86.5% | 87% | |||
Impulse current | 18A/115V 36A/230V | ||||||||
Leakage current | <3.5mA/240VAC | ||||||||
Protection characteristics | Overload protection | 105%~135% | |||||||
Protection way: current limiting, automatic recovery | |||||||||
Overvoltage protection | 115%~135% | ||||||||
Protection way: hiccups, auto recovery mode | |||||||||
environment | Working temperature, humidity | -10℃~+50℃;20%~90 %RH | |||||||
Keep temperature, humidity | -20℃~+85℃;10%~95 %RH | ||||||||
Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | ||||||||
security | Compression sex | 3: KVAC between input and output and input and output KVAC: 1.5 to: 0.5KVAC |
|||||||
Insulation resistance | Between the input and output, the input and output, and ground: 100M Ohms/500VDC |
||||||||
standards | Insulation resistance | Accord with UL1950,TUV EN60950 |
|||||||
EMC standard | Accord with EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204 |
||||||||
other | weight | 1.5Kg | |||||||
packaging | 15pcs/22.5kg/1.22CUFT | ||||||||
note | All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25℃ conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. |