4000W 0-600V 6.6A DC Output Adjustable Switching Power Supply
Output Power: 4000W
Output Voltage: 0-600V DC Adjustable
Output Current: 6.6A
Quality: Government Engineering
- Output Power
- 4000W
- Output Voltage
- 0-600V DC Adjustable
- Output Current
- 6.6A
- Input Voltage
- AC200-240v
- Brand
- SSPELE
- Application
- Hospital,Engineering Project,Electric Lab,LED Lighting etc.
- Quality
- Government Engineering,ISO9001,CE&Rohs,UL
- Payment
- T/T, L/C, Western Union,Paypal,MoneyGram
- Quantity
- 100000 PCS Per Month
- Packing
- Suitable Packing For Sea / Air Transport
- Material
- Aluminum,PCB
- Place of Origin
- Zhejiang,China
- Ripple&Noise
- 150mVp-p
Features:
- High efficiency, high reliability
- For AC power supply input global
- 100% full load and machine test
- Protection characteristics: short circuit/overload/pressure
- Built-in dc electric fan forced air cooling
- Built-in fan switch control
- PFC correction, built-in distance open/shutdown and voltage compensation signal interface
- Size: 405*223*155mm(L*W*H)
- Output Voltage Customized: 0-24/30/36/40/48/60/70/80/90/100/110/120/150/180/200/220/250/300/400/500/600/700/800V DC Adjustable
model | SHA-4000 -300 |
SHA-4000 -200 |
SHA-4000 -150 |
SHA-4000 -100 |
SHA-4000 -80 |
SHA-4000 -48 |
SHA-4000 -600 |
|
output | Dc output voltage | 0-300V | 0-200V | 0-150V | 0-100V | 0-80V | 0-48V | 0-600V |
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated output current | 13A | 20A | 26A | 40A | 50A | 83A | 6.6A | |
Output current range | 0-13A | 0-20A | 0-26A | 0-40A | 0-50A | 0-83A | 0-6.6A | |
Output power | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | 4000W | |
Ripple and the noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
Dc voltage adjustable scope | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | ±0-100% | |
Start, rise, keep time | 200ms,50ms,30ms full Loaded with 230VAC | |||||||
input | Input voltage range | 200-240VAC | ||||||
Frequency | 47-63Hz | |||||||
Exchange input current | None | |||||||
efficiency | 86% | 82% | 83% | 85% | 86% | 86% | 86% | |
Impulse current | 20A/115V 40A/230V | |||||||
Leakage current | <3.5mA/240VAC | |||||||
Protection characteristics | Overload protection | 115%~135% | ||||||
Protection way: cut off the output,reset, automatic recovery | ||||||||
Overvoltage protection | 120%~140% | |||||||
Protection way: hiccups, auto recovery mode | ||||||||
environment | Working temperature, humidity | -10℃~+60℃;20%~90 %RH | ||||||
Keep temperature, humidity | -20℃~+85℃;10%~95 %RH | |||||||
Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | |||||||
security | Compression sex |
L/P-O/P: 1.5KVAC , L/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC (one minute) |
||||||
Insulation resistance |
L/P-O/P, L/P-FG,O/P-FG : 500VDC / 100M ohms |
|||||||
standards | Insulation resistance | Accord with GB4943,UL60950,EN60950 |
||||||
EMC standard | Accord with EN55022, GB9254 |
|||||||
other | weight | 12Kg | ||||||
packaging | 1pcs/12kg | |||||||
note | All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. |