1800W 0-200VDC 9A Output Adjustable Switching Power Supply
Output Power: 1800W
Output Voltage: 0-200V DC Adjustable
Output Current: 9A
- Output Power
- 1800W
- Output Voltage
- 0-200V DC Adjustable
- Output Current
- 9A
- Input Voltage
- AC200-240V
- Brand
- SSPELE
- Application
- Lab,Hospital,Industry,LED Lighting,Charging
- Quality
- Government Engineering
- Payment
- T/T,Paypal,Western Union,L/C
- Material
- Metal,PCB
- Place of Origin
- China
- Ripple&Noise
- 200mVp-p
|
|||||||||
model | SHA-1800 -300 |
SHA-1800 -200 |
SHA-1800 -150 |
SHA-1800 -100 |
SHA-1800 -80 |
SHA-1800 -60 |
|||
output | Dc output voltage | 0-300V | 0-200V | 0-150V | 0-100V | 0-80V | 0-60V | ||
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |||
Rated output current | 6A | 9A | 12A | 18A | 22A | 30A | |||
Output current range | 0-6A | 0-9A | 0-12A | 0-18A | 0-22A | 0-30A | |||
Output power | 1800W | 1800W | 1800W | 1800W | 1800W | 1800W | |||
Ripple and the noise | 300mVp-p | 280mVp-p | 260mVp-p | 240mVp-p | 200mVp-p | 180mVp-p | |||
Dc voltage adjustable scope | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | -10%,+10% | |||
Start, rise, keep time | 200ms,50ms,30ms Loaded with | ||||||||
input | Input voltage range | 200-240VAC | |||||||
Power factor | PF>0.85/230VAC PF>0.85/115VAC Loaded with | ||||||||
Exchange input current | 25A/115 V 50A/ 230 V | ||||||||
efficiency | 86% | 82% | 83% | 85% | 86% | 86% | |||
Impulse current | 10A/115V 5A/230V | ||||||||
Leakage current | <3.5mA/240VAC | ||||||||
Protection characteristics | Overload protection | 115%~135% | |||||||
Protection way: current limiting, automatic recovery | |||||||||
Overvoltage protection | 120%~140% | ||||||||
Protection way: hiccups, auto recovery mode | |||||||||
environment | Working temperature, humidity | -10℃~+60℃;20%~90 %RH | |||||||
Keep temperature, humidity | -20℃~+85℃;10%~95 %RH | ||||||||
Vibrate resistance | 10~500Hz,2G 10min./ 1 cycle time, 60 minutes, the axis | ||||||||
security | Compression sex | 3: KVAC between input and output and input and output KVAC: 1.5 to: 0.5KVAC |
|||||||
Insulation resistance | Between the input and output, the input and output, and ground: 100M Ohms/500VDC |
||||||||
standards | Insulation resistance | Accord with UL1012,EN55022 |
|||||||
EMC standard | Accord with EN55022 |
||||||||
other | weight | 7.5Kg | |||||||
packaging | 1pcs/7.5kg | ||||||||
note | All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25 ℃conditions measuring income value. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. Specific output current see output drop forehead curve. |