1000W 0-400VDC 2.5A Output Adjustable Switching Power Supply with CE
Features: High reliability, low ripple Switch input voltage range choice Protection characteristics: short circuit/ov
- Output Power
- 1000W
- Output Voltage
- 0-400VDC Adjustable
- Output Current
- 2.5A
- Brand
- SSPELE
Features: High reliability, low ripple Switch input voltage range choice Protection characteristics: short circuit/overload/pressure/thermal Built-in distance open/shutdown and voltage compensation signal interface Has the parallel function Built-in dc electric fan forced air cooling Size : 265*186*70mm (L*W*H)
|
||||||
model | SHA-1000-800 | SHA-1000-600 | SHA-1000-500 | SHA-1000-400 | ||
output | Dc output voltage | 0-800V | 0-600V | 0-500V | 0-400V | |
Output voltage tolerance | ±1% | ±1% | ±1% | ±1% | ||
Rated output current | 1.2A | 1.6A | 2A | 2.5A | ||
Output current range | 0-1.2A | 0-1.6A | 0-2A | 0-2.5A | ||
Output power | 1000W | 1000W | 1000W | 1000W | ||
Ripple and the noise | 500mVp-p | 500mVp-p | 500mVp-p | 500mVp-p | ||
Dc voltage adjustable scope | ||||||
Start, rise, keep time | 800ms, 50ms, 16ms Loaded with | |||||
input | Input voltage range | 100~120VAC / 200~240 VAC47~63 Hz | ||||
Exchange input current | 13A/115 VAC 8.0A/ 230 VAC | |||||
efficiency | 80% | 81% | 85% | 87% | ||
Impulse current | 60A/230V | |||||
Leakage current | 3.5 mA/240VAC | |||||
Protection characteristics | Overload protection | 110%~135% | ||||
Protection way: current limiting, delay shut off, restart | ||||||
Overvoltage protection | 110%~135% | |||||
Protection way: cut output, restart | ||||||
High temperature protection | TSW1 (power tube) temperature > 100 ℃, restart when cut off output | |||||
environment | Working temperature, humidity | -10℃~+65℃,20%~90 %RH | ||||
Keep temperature, humidity | -20℃~+85℃,10%~95 %RH | |||||
Vibrate resistance | 10~200Hz,2G 10min.. / 1 cycle time, 60 minutes, the axis | |||||
security | Compression sex | I/P-O/P, I/P-FG:1500VAC | ||||
Insulation resistance | I/P-O/P, I/P-FG, >100M Ohms / 500VDC | |||||
standards | Safety standards | Accord with UL1950,CSA22.2,IEC60950 |
||||
EMC standard | Accord with FCC Part 15 Class A |
|||||
other | weight | 4.5Kg; | ||||
packaging | 8pcs/34.0kg/CARTON | |||||
note | 1. All the parameters in has not specified, all is in 230 VAC voltage input, rated load and 25℃ conditions measuring income value. 2. Ripple and noise voltage is in 20 MHz bandwidth oscilloscope take 12 inches twisted pair end with 0.1 mu and 47 u when capacitance measurement. 3. Tolerance is voltage setting error, the voltage adjustment rate and adjust the sum total of the current rate. 4. The power to consider as a device installed in final equipment, this equipment must be to make sure it’s EMC index. |